Heald undertook the testing of their Roadblockers and Automated bollards at the following test facilities:
Karco, California USA
TRL, Berkshire United Kingdom
MIRA, Warwickshire United Kingdom
Comparison Table
Product | Test Undertaken | Date of Test | Performance Classification | Impact Energy |
APEX Shallow Mount Bollard | IWA-14 | June 2021 |
IWA 14-1:2013 Bollard V/7200[N2A]/64/90:3.7 |
1137.8kJ |
Synergy (Bridge Bollard System) | IWA-14 | March 2021 |
IWA14-1:2013 Bollard V/7200[N3C]/48/90:4.2 |
640kJ |
Synergy Expansion Joint Unit | IWA-14 | October 2020 |
IWA 14-1:2013 Bollard V/7200[N3C]/48/30:0.2 |
640kJ |
Bridge Bollard System | IWA-14 | January 2020 |
IWA14-1:2013 Bollard V/7200[N3C]/48/30:0.9 |
640kJ |
HT3-Matador 4 | IWA-14 | March 2019 |
IWA14-1:2013 Bollard V/7200[N2A]/80/90:3.2 |
1,820.2 kJ |
HT2-Matador 6 | PAS 68 | March 2019 |
PAS 68:2013 Bollard V/7500(N2)/64/90:0.7/0.0 |
1,211.9 kJ |
Commander 1200 | IWA-14 | December 2018 |
IWA 14-1:2013 Blocker V/7200[N3C]/80/90:0.0 |
1,777.8 kJ |
HT3-EM Matador | IWA-14 | August 2018 | IWA 14-1:2013 Bollard V/7200[N3C]/64/90:1.3 |
1,171 kJ |
HT1-IWA Bollard | IWA-14 | April 2016 | IWA14-1:2013 Bollard V/7200[N2A]/64/90:1.3 | 1,156kJ |
HT2-Matador 3 | IWA-14 | November 2014 | IWA14-1: 2013 Bollard V/7200[N2A]/64/90:0.1 | 1,138kJ |
HT1-Mantis 80 Array | IWA14-1 | September 2014 | IWA14-1: 2013 Bollard V/7200[N2A]/80/90:3.5 | 1,774 kJ |
HT1-Mantis 80 | IWA14-1 | March 2014 | IWA14-1-V/7200[N3C]/80/90:7.5 | 1,772.3 kJ |
HT1-Mantis 64 | PAS 68 | February 2014 | PAS68:2013 Fixed Bollard V/7500[N2]/64/90:0.0/0.0 | 1,852kJ |
HT1-Fixed Raptor | PAS 68 | September 2013 | PAS68:2010 V/7500[N2]/48/90:0.0/0.0 | 677.0 kJ |
HT1-Fixed Matador | PAS 68 | September 2012 | PAS68:2010 V/7500[N2]/48/45 | 670.0 kJ |
HT1-Matador 4 | PAS 68 | April 2012 | PAS68:2010 V/7500[N2]/48/90:0.4/0.0 | 671.0 kJ |
HT1-Viper | PAS 68 | December 2011 | PAS68:2010 V/7500[N3]/80/90: 0 /24.6 | 1720.0 kJ |
HT1-Viper | ASTM | January 2012 | ASTM 2656-07 M50:P1 | 1720.0 kJ |
HT1-Matador 3 | PAS 68 | November 2011 | PAS68 V/7500[N2]/48/90:0.0/0.0 | 659.0 kJ |
HT1-Raptor | PAS 68 | March 2010 | PAS68:Blocker/Bollard V/7500[N3]/80/90: 3.3/18.9 | 1889.0 kJ |
HT1-Raptor | ASTM | November 2011 | ASTM: M50-P1 Zero Penetration (SD-STD2.01 K12) | 1737.0 kJ |
HT1-Raptor | ASTM | November 2011 | ASTM: C40 P1 Zero Penetration | 181.0 kJ |
HT1-Sparta 80 | PAS68 | June 2010 | PAS68:Fixed Bollard V/7500[N3]/80/90:10.6/11.1 | 1856.0 kJ |
HT1-Sparta 48 | PAS68 | September 2009 | PAS68:Fixed Bollard V/7500[N2]/48/90:0.0/0.0 | 639.0 kJ |
HT1-Commander | PAS 68 (30) | March 2009 | PAS68:Retractable Blocker V/30000[N3]/80/90: 0.0/6.9 | 7411.0 kJ |
1200 Roadblocker (Test 2) | USA DOS K12 | February 2007 | TRL Report UPR/SSI/079/07K12 Certification | 1679.0 kJ |
1200 Roadblocker | PAS 68 | November 2006 | PAS68:Retractable Blocker V/7500[N3]/80/90: 0.0/14.3 | 1765.1 kJ |
880 Roadblocker | PAS 68 | August 2006 | PAS68 V/7500[N2]/80/90 : 0/25 | 1808.7 kJ |
650 Roadblocker | USA DOS K8 | July 2003 | DOS K8 | - |
Autobollards | USA DOS K8 | July 2003 | DOS K8 | - |